Buy Fingertip Pulse Oximeter oxygen monitor non-invasive SpO2 medical from auto-gadget.com, 100% Satisfaction Guaranteed, Best Price Guaranteed. We accept paypal payment, you can also pay by credit card on paypal. Do you sell (or want to sell) Fingertip Pulse Oximeter oxygen monitor non-invasive SpO2 medical? Please contact us for wholesale prices if you're ordering in larger quantities.
display mode: OLED display
spo2 measuring range:0%~100%, (the resolution is 1%).
accuracy:70%~100%:±2%, below 70% unspecified.
pr measuring range: 30bpm~250bpm, (the resolution is 1bpm)
accuracy:±2bpm or ±2% (select larger)
pulse intensity display: columniation display
power supply: 1.5v (aaa size) alkaline batteries X 2, adaptable range: 2.6v-3.6v
power consumption: smaller than 25ma
battery working hour: theoretical number is 20hours.
safety type: interior battery,bf type
optical sensor: red light---wavelength is 660nm, 6.65mw
infrared---wavelength is 880nm, 6.75mw
dimension: 5.7(l) X 3.1(w) X 3.2(h) cm
weight: 28g (no batteries)/ 1oz
measurement performance in weak filling condition: spo2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. spo2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
resistance to surrounding light: the deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
environments requirements: storage environment:
a) temperature: -40°c-+60°c
b) relative humidity:≤95%
c) atmospheric pressure: 500hpa-1060hpa
operating environment:
a) temperature: 10°c--+40°c
b) relative humidity:≤75%
c) atmospheric pressure: 700hpa-1060hpa
features:
1. integrated with spo2 probe and processing display module
2. small in volume, light in weight, easy in usage and convenient in carrying
3. operation of the product is simple ,low power consumption
4. spo2 value display
5. pulse rate value display, bar graph display
6. low-voltage indication:
low-voltage indicator appears before working abnormally which is due to low-voltage
7. automatically power off function:
when the device is under the state of measuring interface, it will automatically power off within 8 seconds if the finger falls out of probe.
8. major applications & scope of application:
1) used to measure human hemoglobin saturation and pulse rate through finger
2) indicate the pulse intensity by the bar-display
3) suitable in family, hospital(ordinary sickroom), oxygen bar, social medical organizations
4) not suitable for use in continuous supervision for patients
5) not recommended to be used when the patient is suffering from toxicosis which caused by carbon monoxide as the problem of overrating would emerge
package:
1x pulse oximeter
1x hanging rope
1x user manual